  • Construction Defects Created Vulnerable Structure
  • Tower Failure Remains Possible
  • Ground Conditions Ruled Out
Feds blame construction flaws for Champlain Towers collapse

Federal investigators released their most detailed assessment yet of the Champlain Towers South collapse, pinpointing construction flaws and design deficiencies as the primary causes of the disaster that killed 98 people four years ago today in Surfside, Florida.

The National Institute of Standards and Technology issued a comprehensive 90-minute video update Monday outlining preliminary findings that point to widespread problems with the building's original design and construction that created what investigators called "many potential failure initiation possibilities."

User avatar
Curated by
mikeharb
3 min read
Published
5,963
125
nist.gov favicon
National Institute of Standards and Technology
NIST Releases Extensive Video Update on Champlain Towers ...
cbsnews.com favicon
CBS Miami
Preliminary report released on Surfside condo collapse - CBS News
canada.constructconnect.com favicon
constructconnect.com
Investigators getting closer to determining technical cause of ...
Surfside, Florida Champlain Towers South condo collapse ...
npr.org
Construction Defects Created Vulnerable Structure

NIST investigators identified several higher-likelihood scenarios for the collapse, with the pool deck's structural failure emerging as the leading theory. The team found that steel reinforcement was not placed where it should have been, "leading to significantly diminished strength of the pool deck slab and slab-column connections," according to investigative lead Judith Mitrani-Reiser.1

The building's structural design was also "understrength" relative to 1979 building code requirements, creating dangerously low safety margins from the start.1 Heavy planters that were not in the original design, along with sand and pavers added during a pool deck rehabilitation decades later, increased loads on an already inadequate system.1

Glenn Bell, the investigation's co-lead, said corrosion of steel reinforcement in the pool deck concrete further weakened the structure. Water penetration and corrosion also affected basement columns due to "prolonged exposure to water due to ponding and flooding in the garage."1

nist.gov favicon
1 source
Tower Failure Remains Possible

While investigators found "strong evidence that the collapse initiated in the pool deck," they have not ruled out that failure began in the tower itself.1 Bell noted that some of the same design and construction problems found in the pool deck were evident in the building tower, presenting "other plausible hypotheses."1

The team considers it a higher likelihood that the collapse was initiated by either diminished column strength in the tower or failure of a slab-beam-column joint in the southernmost column line where the tower joined the pool deck.1

nist.gov favicon
1 source
Ground Conditions Ruled Out

Investigators determined there is lower likelihood that underground issues caused the collapse. Satellite data showed no ground settling in the five years before the collapse, and studies found no evidence of karst voids in the limestone foundation.1 Laboratory testing showed adequate pile concrete strength.1

The investigation, which has cost more than $30 million, is expected to produce a final report in 2026.1 The team has reviewed two dozen potential failure scenarios using physical evidence, computer modeling, witness interviews and laboratory testing.1

nist.gov favicon
1 source
Related
How did construction flaws specifically weaken the pool deck structure
What role did design deficiencies play in the building's collapse risk
Could earlier warnings about deterioration have prevented the disaster
Discover more
Building collapse in Karachi kills at least 6 people
Building collapse in Karachi kills at least 6 people
A five-story residential building collapsed Friday morning in Karachi's densely populated Lyari neighborhood, killing at least six people and trapping others beneath the rubble, officials said. The incident highlights Pakistan's ongoing struggle with unsafe housing as rescue teams worked through the day to locate survivors in the debris of what authorities had previously declared a dangerous...
694
National Grid ignored 7-year warning before Heathrow fire
National Grid ignored 7-year warning before Heathrow fire
A fire that forced the closure of Europe's busiest airport and stranded more than 200,000 passengers was caused by a technical fault that National Grid had known about for seven years but failed to fix, according to a damning report released Wednesday. The National Energy System Operator found that moisture detected at the North Hyde electrical substation in July 2018 ultimately caused the...
4,996
Meteor explodes over Georgia, punches hole in home's roof
Meteor explodes over Georgia, punches hole in home's roof
A daytime meteor exploded over Georgia Thursday with the force of 20 tons of TNT, sending a pressure wave that rattled windows across the Southeast and punched a hole through the roof of a Henry County home in what NASA confirmed as a rare celestial impact. The three-foot-wide space rock, weighing more than a ton, disintegrated 27 miles above West Forest, Georgia, at 12:25 p.m. after streaking...
11,134
Scottish council approves costly RAAC repairs for evacuees
Scottish council approves costly RAAC repairs for evacuees
Clackmannanshire Council today approved repair options for homeowners whose properties were evacuated due to unsafe concrete, with individual costs ranging from £24,846 to £44,202 per flat owner. The decision comes nearly two years after 30 families were forced from their homes when reinforced autoclaved aerated concrete (RAAC) was found in poor condition across three apartment blocks in...
361